Glass, ACP & Structural Glazing Sealing
Silicone weather-sealing, structural glazing leak repairs and ACP joint rectification for IT parks and commercial towers.
When does your building need this?
Glass and ACP facades leak when old silicone breaks down under UV and wind pressure. Water then reaches office floors, ceilings and electrical services. We replace the failed sealant from cradles or ropes, often outside working hours, so tenants are not disturbed.
- Water inside offices along window or curtain wall lines
- Cracked, shrunken or missing silicone joints
- Whistling or air leaks at glazing joints
- Stains below ACP panel joints
- Leaks only during wind-driven rain
Why it happens, and why the quick fix fails
Older acetic silicones degrade with UV exposure and constant wind vibration. Once they lose adhesion, wind pressure drives rain straight through the joint.

Technical workflow
Every stage is logged with photos and shared with your RWA or estate manager.
- STEP 01
Joint inspection
Leaking joints are traced, often with targeted water testing.
- STEP 02
Strip old sealant
Degraded silicone is cut out fully from glazing beads and ACP joints.
- STEP 03
Clean and prime
Joints are solvent-cleaned, backer rods installed and primer applied where specified.
- STEP 04
Re-seal
Joints are re-sealed with neutral-cure weatherproof silicone and tooled.
- STEP 05
Water test
Sealed areas are tested before handover.
Approved material systems
Factory-sealed branded materials, with technical data sheets submitted before work starts. Final selection depends on the audit.
| Application area | Recommended system | Key technical benefit | Approved brands |
|---|---|---|---|
| Glazing & ACP joints | Neutral-cure weatherproof silicone | UV-stable, does not corrode frames | Dow Corning / Sika |
| Wide joints | Backer rod + silicone | Correct depth for long sealant life | Approved systems |
Common questions
Can the work be done without disturbing offices?
Yes. We can schedule work at weekends or outside office hours and work entirely from outside.
Do we need bamboo scaffolding for a 15 to 25 floor tower?
No. We use certified double-rope access systems and motorized suspended cradles. This avoids security risks, protects resident privacy, keeps ground parking open and cuts setup time significantly.
How do we verify that genuine branded chemicals are used?
All materials arrive in original, factory-sealed containers. Your RWA or facility representative can check batch numbers, seals and the manufacturer Technical Data Sheets (TDS) before anything is opened.
What does the written warranty cover?
Material adhesion, resistance to film cracking, and waterproofing performance against seepage in all treated areas, backed by a formal QA/QC sign-off sheet. The period depends on the system used and is stated in the proposal.
Not sure this is the right fix? Our free audit finds the cause first, then we recommend the system.
Book a free site auditNeed glass & acp sealing for your building?
Our team maps the moisture and cracks, finds the root cause and gives your committee a written BOQ before any work starts.